VALID FIRE-INSPECTOR-II TEST QUESTION & LATEST FIRE-INSPECTOR-II EXAM QUESTIONS

Valid Fire-Inspector-II Test Question & Latest Fire-Inspector-II Exam Questions

Valid Fire-Inspector-II Test Question & Latest Fire-Inspector-II Exam Questions

Blog Article

Tags: Valid Fire-Inspector-II Test Question, Latest Fire-Inspector-II Exam Questions, Popular Fire-Inspector-II Exams, Dumps Fire-Inspector-II Questions, Fire-Inspector-II Valid Dumps Pdf

The study system of our company will provide all customers with the best study materials. If you buy the Fire-Inspector-II latest questions of our company, you will have the right to enjoy all the Fire-Inspector-II certification training materials from our company. By updating the study system of the Fire-Inspector-II Training Materials, we can guarantee that our company can provide the newest information about the exam for all people. We believe that getting the newest information about the exam will help all customers pass the Fire-Inspector-II exam easily.

There are three versions of Fire-Inspector-II training materials for the candidate of you, and different versions have different advantages, you can use it in accordance with your own habit. Free update for each version for one year, namely, you don’t need to buy the same version for many times, and the update version will send to you automatically. You will get the latest version of Fire-Inspector-II Training Materials.

>> Valid Fire-Inspector-II Test Question <<

Try the Free International Code Council Fire-Inspector-II Exam Questions Demo

So many candidates have encountered difficulties in preparing to pass the Fire-Inspector-II exam. But our study materials will help candidates to pass the exam easily. Our Fire-Inspector-II guide questions can provide statistics report function to help the learners to find weak links and deal with them. The Fire-Inspector-II Test Torrent boost the function of timing and simulating the exam. They set the timer to simulate the exam and help the learners adjust the speed and keep alert.

International Code Council 67 - Fire Inspector II Exam Sample Questions (Q59-Q64):

NEW QUESTION # 59
Use, dispensing, and mixing of flammable liquids in open systems shall have continuous mechanical ventilation at a minimum rate of ___ CFM per sq. ft. of floor area.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

Explanation:
Reference to Ventilation Requirements for Flammable Liquids:
The International Fire Code (IFC 2021), Section 5004.3.7.3, and NFPA 30 (Flammable and Combustible Liquids Code), Section 18.5.4.1 specify the ventilation requirements for the use, dispensing, and mixing of flammable liquids in open systems.
Continuous mechanical ventilation must be provided at a minimum rate of 2 CFM per square foot of floor area.
Reason for Ventilation Requirements:
Flammable liquids release vapors that can ignite at low concentrations, creating fire and explosion hazards.
Proper ventilation removes vapors to prevent them from reaching flammable limits in the air.
Clarification of Incorrect Answer Choices:
A: 1 CFM per sq. ft. # Incorrect
Too low to effectively control flammable vapor accumulation.
C: 3 CFM per sq. ft. # Incorrect
While more ventilation can be beneficial, the minimum required by code is 2 CFM per sq. ft.
D: 4 CFM per sq. ft. # Incorrect
Exceeds the code-mandated minimum requirement, though higher ventilation rates may be required based on specific hazards.
Conclusion:
The correct and verified answer is B (2 CFM per sq. ft.), based on IFC 5004.3.7.3 and NFPA 30 Section
18.5.4.1, ensuring safe handling of flammable liquids in open systems.


NEW QUESTION # 60
Newly upholstered furniture may be required to resist ignition by cigarettes in common areas in which of the following nonsprinklered occupancies?

  • A. Group A-1
  • B. Office spaces
  • C. Group I-2
  • D. Libraries in Group E

Answer: C

Explanation:
In nonsprinklered occupancies, newly upholstered furniture in common areas must resist ignition by cigarettes primarily in Group I-2 occupancies (such as hospitals, nursing homes, and care facilities). This requirement reduces the risk of fire ignition in environments where occupants may have limited mobility and are unable to evacuate quickly.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 805.2 (Ignition Resistance of Upholstered Furniture and Mattresses) IFC 805.2 specifies that nonsprinklered Group I-2 occupancies must have upholstered furniture that resists ignition by cigarettes because these settings involve vulnerable populations who may need assistance in an emergency.
2. NFPA 101 - Life Safety Code (2021 Edition) - Section 10.3.2 (Fire-Retardant Upholstered Furniture) NFPA 101, Section 10.3.2 aligns with the IFC in requiring that furniture in health care facilities (Group I-2) must meet fire resistance standards to prevent ignition from cigarettes and other sources.
Detailed Explanation of Answer Choices:
Option A (Correct): Group I-2 (hospitals, nursing homes, and assisted living facilities) is required to have cigarette-ignition-resistant upholstered furniture in nonsprinklered common areas.
Option B (Incorrect): Group A-1 (theaters and performing arts venues) does not have this requirement, as seating arrangements are different and typically involve fire-resistant materials.
Option C (Incorrect): Office spaces (Business Occupancies, Group B) do not require ignition-resistant furniture under fire code regulations.
Option D (Incorrect): Libraries in Group E (Educational Occupancies) are not required to have this furniture unless otherwise specified by local codes.
Thus, the correct and verified answer is: A. Group I-2


NEW QUESTION # 61
The occupant load of an R-2 building's common patio area is to be calculated using the value:

  • A. 11 gross per person.
  • B. 50 net per person.
  • C. assigned by the code official.
  • D. 15 gross per person.

Answer: D

Explanation:
The occupant load for an R-2 building's common patio area must be calculated using an occupant load factor.
The correct factor is 15 gross sq. ft. per person.
Reference to Fire Inspector Documentation:
1. 2021 International Building Code (IBC) - Table 1004.5 (Occupant Load Factor) For outdoor areas (such as patios and terraces), the applicable factor is 15 gross sq. ft. per person.
2. 2021 International Fire Code (IFC) - Section 1004.5 (Outdoor Occupant Loads) The 15 gross per person requirement is applied to common outdoor gathering areas in residential occupancies (R-2).
Detailed Explanation of Answer Choices:
Option A (Incorrect): 50 net per person applies to storage areas, not patios.
Option B (Incorrect): 11 gross per person is used for business occupancies (B), not residential patios.
Option C (Correct): 15 gross per person is the correct calculation factor for common outdoor spaces in R-2 buildings.
Option D (Incorrect): The code official does not assign occupant load values arbitrarily-they follow IBC Table 1004.5.
Thus, the correct and verified answer is: C. 15 gross per person.


NEW QUESTION # 62
What fire-resistance rating is required for interior nonbearing wall and partitions in Type IV construction?

  • A. 1 hour
  • B. 0 hours
  • C. 2 hours
  • D. 1-1/2 hours

Answer: B

Explanation:
The fire-resistance rating requirements for different building elements in Type IV (Heavy Timber) construction are specified in the 2021 International Building Code (IBC), Table 601 - Fire-Resistance Rating Requirements for Building Elements (Hours).
IBC Table 601 - Fire Resistance for Type IV Construction:
Interior nonbearing walls and partitions in Type IV construction require 0 hours of fire resistance.
This is because Type IV construction primarily relies on large, heavy timber elements that provide inherent fire resistance.
Why Other Options Are Incorrect?
B: 1 hour - Incorrect, as nonbearing interior walls in Type IV construction are not required to have a fire- resistance rating.
C: 1-1/2 hours - Not required by code.
D: 2 hours - Only structural elements like exterior walls in some cases may require fire resistance, but nonbearing interior partitions do not.


NEW QUESTION # 63
The minimum working space width for a 66-in. wide electrical equipment panel shall be in

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

Explanation:
Minimum Working Space Width for Electrical Equipment Panels
According to National Electrical Code (NEC) 110.26(A)(2) and International Fire Code (IFC) 2021, Section
604.3, the minimum working space width for electrical equipment must be at least the width of the equipment or 30 inches, whichever is greater.
Since the equipment panel in the question is 66 inches wide, the required working space width must be at least 66 inches.
2. Why 66 Inches is the Correct Answer
The minimum clearance width must be equal to the width of the electrical equipment if the panel itself is wider than 30 inches.
This ensures safe maintenance and emergency access to electrical components.
3. Verification of Other Options
Option A (30 inches) - Incorrect, because the equipment is wider than 30 inches, requiring a larger clearance.
Option B (36 inches) - Incorrect, as this is not the requirement for a 66-inch-wide panel.
Option D (78 inches) - Incorrect, as the clearance does not need to exceed the width of the panel.
Reference Sources:
National Electrical Code (NEC) 2023 - Section 110.26(A)(2) (Working Space Width Requirements) International Fire Code (IFC) 2021 - Section 604.3 (Electrical Equipment Clearance Requirements) ICC Fire Inspector II Study Guide (2021)


NEW QUESTION # 64
......

Under the dominance of knowledge-based economy, we should keep pace with the changeable world and renew our knowledge in pursuit of a decent job and higher standard of life. In this circumstance, possessing a Fire-Inspector-II certification in your pocket can totally increase your competitive advantage. Therefore our Fire-Inspector-II Study Guide can help you with dedication to realize your dream, and our Fire-Inspector-II training guide is a great opportunity for you to improve working efficiency and make the process of our work more easily and smoothly.

Latest Fire-Inspector-II Exam Questions: https://www.itpassleader.com/International-Code-Council/Fire-Inspector-II-dumps-pass-exam.html

We really want to help you solve all your troubles about learning the Fire-Inspector-II exam, International Code Council Valid Fire-Inspector-II Test Question Nowadays, seldom do the exam banks have such an integrated system to provide you a simulation test, I will introduce you to the advantages of our Fire-Inspector-II exam torrent, If you come to visit our website more times, you will buy our Fire-Inspector-II practice engine at a more favorable price, With the help of our Fire-Inspector-II dumps, you can pass your certification exam very easily.

Even though you will be guaranteed unique numbers, you are not guaranteed Fire-Inspector-II contiguous numbers, I could turn any executive project dashboard into a work of art, with colors, charts and lots of bling.

Marvelous International Code Council Valid Fire-Inspector-II Test Question With Interarctive Test Engine & Authoritative Latest Fire-Inspector-II Exam Questions

We really want to help you solve all your troubles about learning the Fire-Inspector-II Exam, Nowadays, seldom do the exam banks have such an integrated system to provide you a simulation test.

I will introduce you to the advantages of our Fire-Inspector-II exam torrent, If you come to visit our website more times, you will buy our Fire-Inspector-II practice engine at a more favorable price.

With the help of our Fire-Inspector-II dumps, you can pass your certification exam very easily.